Mechanical and Seal Integrity Testing for Flexible Packaging: A Guide to Quality Assurance
Introduction
A flexible package is only as dependable as its seals. Pouches, sachets, bags and lidded packs are closed by a bond between two layers of material. If that bond is weak, opens, or lets air or liquid through, the package stops protecting what is inside. Studies of heat sealed packaging point out that shelf life depends on two things: how well the package is sealed and how well the material blocks gas and moisture. They also note that spoiled products are often traced back to a faulty seal [9].
Quality teams usually ask two different questions about a seal. The first is how much pulling force the seal can take before it comes apart. The second is whether the seal has any hole or channel that lets gas, liquid or germs through. In medical packaging these are treated as two separate checks. Seal strength is the mechanical strength of the seal. Package integrity is the condition of the finished package when nothing about it is damaged or open [13].
This guide explains the main strength and leak tests used for flexible package seals. It describes what each test can show and what it cannot, how sealing settings change the result, and what to think about when choosing test equipment. It draws on published standards and research papers. Every standard applies only within its own stated scope, so the guide mentions that scope where it matters. It gives no universal pass or fail numbers, because the right limits depend on the package, the material and how the product is used.
Key terms used in this guide
| Term | Meaning in this guide |
|---|---|
| Seal strength | The force needed to pull apart a strip cut from a seal [1][13] |
| Package integrity | The finished package is whole, with no damage, hole or open channel [13] |
| Way of failing | How a test sample breaks: the seal peels open, the layers split apart, or the material tears [1][9] |
| Burst test | Air pressure inside the package is raised until the package fails [3] |
| Hold test | A set pressure is held for a set time, or until the package fails [3] |
| Sealing time | How long heat and pressure are applied while the seal is made [9] |
| Safe operating range | The set of sealing conditions that give good seals [11] |
| Early seal strength | How strong a seal is right after sealing, before it has cooled. Specialists call this hot tack [14] |
Table 1. Terms explained
Seal Strength and Seal Integrity: Two Different Questions
Seal strength is a number you can measure. It is useful for proving that a sealing process works, for keeping it under control, and for judging how steady it is. It relates to the force a person needs to open the package and to whether the package stays closed. It also shows whether the packing line makes consistent seals [1]. A leak test asks something else: is there any path through which air, liquid or germs could pass? The two answers do not depend on each other, so a good quality program normally uses tests from both groups.
| Method | Standard | What it checks | Limit stated in the standard |
|---|---|---|---|
| Seal peel (pull test) | ASTM F88 [1] | The force needed to pull apart a strip containing the seal, and how it fails | Reflects only the strip tested. It does not copy a person opening the whole package |
| Burst and hold, package free to expand | ASTM F1140 [3] | How well a package resists pressure from inside | Results do not necessarily match seal strength measured by F88 |
| Burst, package held between plates | ASTM F2054 [2] | The lowest burst strength of a seal around the edge of a pouch | Cannot show how even the seal is, or whether the whole package is leak tight |
| Bubble test | ASTM F2096 [4] | Large leaks in tray and pouch packages | Destroys the package. Stated sensitivity is 250 µm at an 81 % chance of detection |
| Dye test | ASTM F1929 [5] | Leak channels along the edge seal | Written for particular package types. Usually gives a pass or fail answer |
Table 2. Common test methods for flexible package seals
Two practical points follow. A seal can meet its strength limit and still hide a leak channel. A package can also pass a leak test while its seals are too weak for handling or sterilization. Neither result replaces the other.

Figure 1 shows the idea behind a peel test. A strip that contains the seal is cut from the package, and the force needed to separate it is recorded [1]. Everything else in the method, such as how the strip is held and how the result is reported, exists to make that one measurement repeatable.
Pull Testing of Seals (ASTM F88)
What the method measures
ASTM F88 covers the measurement of seal strength in flexible barrier materials. The seal can join a flexible material to another flexible, rigid or semi rigid material, and the sample can come from a laboratory or from normal production. The test records the force needed to pull apart a strip containing the seal. It also records how the sample fails [1]. The standard points out that it is different from F2824, which measures the strength of a seal when a whole lid is pulled off a rigid or semi rigid round container [1].
Why the way the strip is held matters
Part of the force you record in a peel test can come from bending the material rather than from the seal itself. For this reason F88 describes three ways to hold the sample. In Technique A the seal is left unsupported. In Technique B the seal is held at a right angle by hand. In Technique C the stiffer tail lies flat against a rigid plate while the more bendable tail is folded back over the seal. Each way gives a different result, so the standard advises using the same one throughout a test series [1].

The standard also notes that some flexible materials can slip or flip during the test. That can change the result and should be reported. When a lab checks its method, it should account for any fixtures or alignment plates and for which material goes into which grip [1]. A review in the trade press makes the same point in simple terms: results taken with different holding methods cannot be compared with each other [12].
Reading the result
F88 says the highest force reached is important. For some uses the average force needed to open the seal is also helpful, and then it should be reported too [1]. The standard also separates lower limits from upper limits. A minimum strength gives confidence that the package will stay closed. A maximum is normally set only for seals that the customer is meant to peel open [1].
A research paper on paper based pouches shows how the method is used. The authors followed F88 guidance, pulled strips 25 mm wide, tested six samples for each condition, and let the sealed samples rest for at least 48 hours before testing [9]. These were that study's own choices and are not rules for every lab. The authors also used the way each sample failed to read their results. When the seal was stronger than the paper, the layers split apart or the coating tore instead of the seal opening [9].
Sample width and preparation
A review in the trade press gives the sample width for F88 as 25.4 mm, which is one inch [12]. The paper based pouch study used 25 mm strips [9]. Whichever width you choose, write it down and keep it the same from test to test. The standard itself remains the authority on what samples must look like [1].
Burst and Pressure Testing
Testing a package that can expand freely (ASTM F1140)
ASTM F1140 explains how to find out whether a package can withstand pressure from inside. In a burst test the pressure is raised until the package fails. In a hold test a chosen pressure is kept for a chosen time, or until the package fails [3]. The standard calls these quick ways to judge how a package may behave when pressure differs inside and outside, for example during sterilization or transport. It adds that they are often used during manufacturing and at many stages of a package's life [3].
F1140 warns that results from different machines can only be compared if every test setting is the same. Settings that matter include package size, material, seal layout, test machine, the rate at which air enters the package, how quickly the machine reacts to a pressure drop, and where the package sits [3]. It also states that these tests do not necessarily agree with the seal strength measured by F88 [3].
Testing a package held between plates (ASTM F2054)
F2054 explains that when a package is free to expand, the stress is not spread evenly across all parts of the seal [2]. ASTM F2054 therefore places the package between two plates. The plates keep the package at a steady thickness and spread the stress more evenly along the seal around the edge. The method is meant for flexible packages sealed all the way around, which are commonly called pouches [2].
F2054 lists the settings that can change the result: package size, material, seal type and layout, the rate of air flow into the package, the sensor that reads pressure and how sensitive it is, where the package sits, how stiff the plates are, and how far apart they are. It warns that anyone who builds their own plates must take special care [2]. If the package material lets air pass through, the air supply may be too small to reach the pressure needed to burst the seals [2].
The standard is just as clear about what the test cannot do. It indicates the lowest burst strength, but it cannot measure how even the seal is or whether the whole package is leak tight. It may not match results from F1140 or F88, so it should be combined with other methods when those qualities matter [2].

How pull tests and pressure tests relate
According to a review by a specialist in test equipment, nobody has defined a single formula linking pull tests and pressure tests. Research on pouches has, however, shown that pressure tests with the package held between plates correlate with pull tests. The same review reports that the held test finds the weakest part of a pouch seal more reliably. It also says that seal strength values depend on package size, shape, materials and bonding agents, so there is no single required value [12]. In practice, a lab should set limits for each package design and not borrow numbers from another product.
The review adds that pressure tests can be used on seals that are meant to peel open and on seals that are not [12]. A pull test samples a strip of the seal, while a pressure test loads the whole package. The right choice depends on whether your question is about the seal material and process or about the finished package.
Leak Testing
A strength test asks how much load a seal can carry. A leak test asks whether the package is actually closed. Two methods show how different the approaches can be.
- Bubble test (ASTM F2096). The package is filled with air under pressure and checked for large leaks. The standard covers tray and pouch packages. It states a sensitivity down to 250 µm at an 81 % chance of detection. It says that sensitivity has not been checked for porous materials other than one type of spun polyolefin, or for packaging that is not porous. The test destroys the package, because it must be opened to supply the air pressure [4].
- Dye test (ASTM F1929). A coloured liquid is applied along the seal edge and the package is inspected for dye seeping through. Earlier editions of the standard describe the test as good at locating leaks but not able to measure them, and as normally used for pass or fail decisions. They also say there is no general agreement on how much leakage is harmful for a given package [5].
The right choice depends on the package. Earlier editions of F1929 describe a method written for edge seals between a clear film and a porous sheet [5]. It is not automatically suitable for a pouch made only of film. In the same way, a method with a stated sensitivity limit should be picked with that limit in mind. Reading the scope of each standard before using it prevents most misuse.
Where ISO 11607 fits
ISO 11607 Part 1 sets out requirements and test methods for materials and packaging systems that keep medical devices sterile until the moment of use, when the devices are sterilized in their final package. It was last confirmed in 2024, and a 2023 amendment covers risk management [7]. Part 2 covers how to develop and prove the forming, sealing and assembly steps [8].
These documents apply to medical devices sterilized in their final package. They are not general standards for food or consumer packaging. A trade press overview explains the logic: a package testing process that can be proven must include both a leak check and a seal strength check [13].
How Sealing Settings Shape the Seal
Testing is only half of seal quality, because the strength of a seal is created while the seal is made. When a seal is made with heat, the sealing layers partly melt under heat and pressure. Molecules from each side move across the boundary, and as the material cools they tangle together and form the bond [9]. Three settings matter most: temperature, sealing time (how long heat and pressure are applied) and pressure.

ASTM F2029 describes how to make seals in a laboratory with a hot bar or an impulse sealer. It treats the strength measured by F88 as the only measure of how well a material seals. It does not cover whether the seal is leak tight, such as with air leak or dye tests, and it does not cover early seal strength, which is handled by another method, ASTM F1921. It is meant to help find starting settings, and more guidance may be needed to set up production machines [6].
| Setting | What it does | What the cited studies found |
|---|---|---|
| Temperature | Melts the sealing layer enough for the molecules to mix | The main factor for strength in laminates with polyethylene sealing layers [11]. Higher temperature helped in coated polypropylene film [10]. The first seals appeared at 90 °C on paper based material and 100 °C on a plastic film, with a 2 second sealing time [9] |
| Sealing time | Gives the heat time to reach the seal boundary | Must be long enough to bring the boundary to the right temperature. After that, more time adds nothing [11]. Not a major factor on its own in coated polypropylene [10] |
| Pressure | Presses the surfaces together | Little effect once it is enough to flatten the materials [11]. Little effect above about 3 bar for paper based material [9]. The largest effect, and a negative one, in coated polypropylene [10] |
| Shape of the sealing tool | Sets the contact area and local stress | A ridged tool gave slightly lower seal strength than a flat tool on paper based material [9] |
Table 3. Sealing settings and what published studies report
The studies do not agree on every point, and the reason is useful to know. The pressure result for coated polypropylene differs from the results for polyethylene laminates and paper based material because the structures, coatings and test designs were different [9][10][11]. The lesson for quality teams is that the effect of each setting must be found for each material and package, and not copied from published numbers.
Safe operating ranges and how seals fail
One study of laminates with polyethylene sealing layers used a laboratory sealer to map out the range of settings that gave good seals for each film. It found that seal strength and the way the seal fails are closely linked. It also found that the temperature at which strength levels off matches the final melting point of the sealing layer [11]. Working well inside such a range, and not at its edge, is what makes later strength and leak tests meaningful.
Ranges also have upper limits. In the paper based pouch study, the paper materials began to turn brown at higher temperatures, and the plastic film shrank around the seal above 140 °C [9]. These observations apply only to the materials that were tested.
Laboratory settings and production machines
The same study found that settings worked out on a laboratory sealer could be moved straight to the vertical machine that forms, fills and seals pouches in production, for the materials tested. This let the production trials start quickly [9]. F2029, by contrast, warns that more guidance may be needed for production machines [6]. A sensible reading is that laboratory results make a strong starting point but must be confirmed on the production machine for each new material.
The condition of the material also matters. In the production trials the paper based material lost moisture, became brittle and tore more easily [9]. Material and samples should therefore be kept in controlled conditions before sealing and testing, and those conditions should be recorded.
Early seal strength and the cooling stage
Early seal strength, known to specialists as hot tack, is the strength of a seal right after it is made, before it has cooled [14]. ASTM F2029 states that this property is outside its scope and points to a separate method, ASTM F1921 [6]. A seal that is strong once cooled therefore tells you nothing for certain about how it behaves in the moments just after sealing. Where line speed makes that difference important, the two properties should be checked separately.
What Experimental Studies Show
Published studies give a useful picture of how sealing settings work together. They should be read as examples of method, because each study applies to its own materials.
A planned experiment on coated polypropylene film
Farris and colleagues studied polypropylene film with a thin coating made from a natural material. They changed several sealing settings together in a planned set of experiments. Pressure had the largest effect on seal strength, and the effect was negative. Temperature had a positive effect. Sealing time did not matter much on its own, but it did matter in combination with pressure [10]. They also compared two ways of describing seal strength. The energy needed to break the seal explained the results much better than the highest force did [10].
Two lessons follow. First, changing one setting at a time can miss effects that only appear when settings are combined, such as time with pressure. Second, the number you choose to report changes how much of the data it can explain.
Laminates with polyethylene sealing layers
Hassan and colleagues examined laminated films with polyethylene sealing layers sealed with a heated bar. The temperature of the heated plates was the main factor. Sealing time had to be long enough to bring the boundary up to temperature, and extra time did nothing more. Pressure mattered little once it was enough to flatten the materials [11]. Films that conduct heat poorly needed hotter plates. Laminates made by extrusion could not reach the seal strength of laminates made with adhesive bonding [11].
Case Study: Heat Sealing Paper Based Pouches
Merabtene and colleagues tested paper based flexible materials for use on a vertical packaging machine that forms, fills and seals pouches. They compared them with a plastic film of stretched polypropylene and polyethylene [9]. The study is a good case because it links laboratory sealing, peel testing in the style of F88, and production trials in one paper.
Method
Seals were made on a laboratory sealer at set temperatures and sealing times. Samples rested for at least 48 hours, were cut into strips 25 mm wide, and were pulled apart in a T shaped peel at 180 degrees. Six samples were tested for each condition. The tester used a 1 kN load cell, a light preload to 0.2 N at 50 mm/min, and then a pull at 300 mm/min [9]. Settings like these should be reported with the results, as the standards advise [1].
Results
With a 2 second sealing time, the first seals appeared at 90 °C for the paper based materials and 100 °C for the plastic film. The paper materials began to brown at about 220 °C and 190 °C for the two constructions tested, and the plastic film shrank above 140 °C [9]. Figure 5 shows these reported limits.
![Temperature from first seal to the start of browning or shrinking, as reported by Merabtene and colleagues [9] (original chart).](/blog-content/article-1709-flexible-packaging-seal-testing/image5.png)
The chart shows that the paper based structures had a much wider gap between the first seal and heat damage than the plastic film did. Only part of that gap gives good seals, so the chart is not a recommended operating range. The left end marks only the first seal seen, and the right end marks the start of damage [9].
Other observations
- The seal strength of the plastic film was about three times that of the paper based materials [9].
- Above about 3 bar, more pressure made little difference to the paper seals [9].
- A ridged sealing tool gave slightly lower strength than a flat tool [9].
- The pouches were not completely airtight, which matters when a package must keep out oxygen or moisture [9].
- When the seal was stronger than the paper, the layers split apart or the coating tore [9].
The authors also found that settings found on the laboratory sealer carried over to the production machine for these materials. They advised keeping a sealing time above 1 second at 100 °C in production [9]. These are findings for those materials and that machine.
Reading Results: How Seals Fail, Variation and Reporting
A single number rarely describes a seal. F88 asks for the way the sample failed alongside the force [1], and research shows why. In the coated polypropylene study, the energy needed to break a seal described seal strength better than the highest force [10]. Reporting only a peak value can hide differences in how seals fail.
A good test report holds enough detail for another lab to repeat the work. Based on the factors the standards name, the record should include:
- The standard, its edition and the technique used, including how the sample was held and which material went in which grip [1].
- For pressure tests, the package size, seal layout, air flow rate, pressure sensor sensitivity and package position. For F2054, add the stiffness and spacing of the plates [2][3].
- The highest force and, where useful, the average force, together with the way the sample failed [1].
- How materials were stored before sealing and testing, and the sealing settings used to make the seals [6][9].
Variation should be examined, not averaged away. When results scatter, check the sealing process first (temperature, time, pressure and the condition of the tool). Then check how the samples were cut and prepared. Last, check the test fixture and technique.
Building a Quality Program Around Seal Testing
Seal tests serve different purposes at different stages. F88 describes seal strength as a measure for proving a process, controlling it and judging how steady it is [1]. ISO 11607 Part 2 covers proving the forming, sealing and assembly steps for medical devices sterilized in their final package [8]. F1140 notes that its tests are often used to judge packages quickly during manufacturing [3]. Table 4 shows one way to organize these roles.
| Stage | Question | Typical methods |
|---|---|---|
| Development | Which sealing settings give good seals for this material? | Laboratory seals made as in F2029 [6], then checked by peel testing as in F88 [1] |
| Proving the process | Does the process reliably make seals that meet the limit? | Seal strength and leak tests. For medical devices, the ISO 11607 requirements [7][8] |
| Routine control | Is production staying inside the proven range? | Peel, burst or hold tests [1][3], and leak checks suited to the package [4][5] |
| Investigation | Why did a package fail? | Study how the peel samples failed [1], and use leak methods to find the leak [4][5] |
Table 4. A staged approach to seal testing
At every stage the specification should name the method and its settings. Standards such as F1140 and F2054 note that results can only be compared when test settings match [2][3]. A specification that names only a pressure or a force, with no method, cannot be reliably repeated.

Troubleshooting guide
Table 5 links common observations to causes named in the cited sources. Treat it as a prompt for investigation and not a diagnosis, because the real cause in a plant depends on the material and the machine.
| What you see | What to investigate |
|---|---|
| The seal does not form, or opens easily | Sealing temperature below the level where the material first seals, or sealing time too short [9][11] |
| The layers split or the material tears instead of the seal peeling | The seal is stronger than the material, so the seal itself is not the weak point [9] |
| Paper based material turns brown or brittle | Sealing temperature too high, or the material has lost moisture [9] |
| Plastic film shrinks or warps around the seal | Temperature above what the film tolerates. One plastic film shrank above 140 °C [9] |
| Different labs report different peel values | A different way of holding the sample, different fixtures or a different grip arrangement [1][12] |
| High burst pressure but low peel strength, or the reverse | The two methods do not necessarily agree [2][3] |
| A porous package will not reach burst pressure | Not enough air flow into the package [2] |
| Strength varies widely between samples | Check the sealing process, then sample preparation, then the test fixture and technique, in that order |
Table 5. Observations and possible causes drawn from the cited sources
Choosing a Seal and Package Tester
Choose equipment by starting from the test plan and not from the catalogue. The standards covered above point to the criteria in Table 6.
| What to check | Why it matters |
|---|---|
| Methods and standards needed | Peel, burst, hold and leak methods are covered by different standards [1][2][3][4]. Confirm from the maker's documents which standards the instrument supports. |
| Package types and sizes | Package size, seal layout and material are listed as settings that affect pressure test results [2][3]. |
| Fixtures | The F88 techniques depend on holding and alignment fixtures [1]. F2054 depends on plates [2]. |
| Pressure and air flow control and sensing | Air flow rate and sensor sensitivity can change results [2][3]. Porous packages may need enough air flow [2]. |
| Data and records | Reports must record test settings and the way each sample failed, so that results can be repeated [1][3]. |
| Safety features | Each standard leaves it to the user to set up safe working practices [1][2][3]. |
Table 6. What to look for in seal and package testing equipment
If you are looking at a particular instrument, such as the Testshine TS-SPT1 Intelligent Sealing Performance Tester, the maker's product documents are the place to confirm supported test modes, standards and package types. Check those details against this list and do not assume them.
Safety, Upkeep and Good Laboratory Habits
The standards cited here do not claim to cover every safety concern. They leave it to the user to set up suitable safety, health and environmental practices [1][2][3]. As with any pressurized test, think about what happens if a package or fixture fails while under pressure, and follow the instrument manual for guards and operator protection. F2054 specifically advises care when building plate fixtures [2].
Servicing and calibration schedules belong in the instrument manual and your lab's quality system, so this guide does not set them. Good habits include recording the equipment and settings used for every test, keeping fixtures and plates in the condition the method assumes, and using the same technique through a whole test series [1][3].
A checklist for a seal testing procedure
- State the standard, its edition and the technique, and the question the test is meant to answer [1][2][3].
- Define the sample width, and how samples are stored and rested before sealing and testing [1][9].
- Record the sealing settings: temperature, time, pressure and tool type [6][9].
- Record how every sample failed, as well as the force [1].
- Keep the holding method, fixtures and grips the same across a test series [1][12].
- For pressure tests, record package size, air flow rate and sensor sensitivity [2][3].
- Confirm laboratory settings on the production machine for each new material [6][9].
Frequently Asked Questions
Is seal strength the same as package integrity?
No. Seal strength is how strong the seal is. Integrity is whether the finished package is whole and closed. Medical packaging practice calls for both [13].
Does a high burst pressure prove a strong peel seal?
Not necessarily. F1140 states that burst and hold results do not necessarily match seal strength from F88, and F2054 says the same about its own results [2][3].
Why do two labs get different F88 results?
The way the sample is held, the fixtures, the grips and any slipping of the tail all affect the result, and results from different holding methods cannot be compared [1][12].
Can a bubble test find every leak?
No. F2096 states a sensitivity down to 250 µm at an 81 % chance of detection, and it has not checked sensitivity for some materials [4].
Can laboratory sealing settings be used directly in production?
They are a starting point. One study found the settings carried over for the materials it tested [9], while F2029 notes that more guidance may be needed for production machines [6]. Confirm on the production machine.
Do these standards apply only to medical packaging?
Not all of them. ISO 11607 and F1929 are written for medical packaging [5][7]. The titles of F88, F1140, F2054 and the 2019 edition of F2096 refer to flexible barrier materials and packages more broadly, but each standard's scope decides where it applies [1][2][3][4].
Conclusion
Reliable flexible packaging needs two kinds of proof: how strong the seal is, and whether the package is truly closed. Peel tests, burst and hold tests, and leak tests each answer part of that question, and each standard states limits that should be read before its results are used. Studies of heat sealing show that the effect of temperature, time and pressure depends on the material, so a safe operating range must be found for each material and confirmed on production machines.
A sound program names the method and its settings in every specification, records how samples fail as well as the force, and chooses test equipment to match the standards and packages the lab actually handles.
Relevant Testshine Product
Explore the Testshine TS-SPT1 Intelligent Sealing Performance Tester
This article covered how seal strength, burst and hold behaviour, and leak tightness are checked for flexible packaging. The Testshine TS-SPT1 Intelligent Sealing Performance Tester is the Testshine instrument listed for sealing performance testing. Its product page is the place to confirm which test modes, standards and package types it supports.
What to check against your test plan:
- Which test modes are offered, for example burst, hold or leak testing.
- Which standards the instrument is documented to support, compared with the standards your customers or regulators require.
- Which package types, sizes and fixtures are supported, including any option for holding packages between plates.
- How results are shown, saved and exported for your quality records.
Matching the instrument to the standards and packages you actually test is what makes the results useful for proving your process and for routine checks.
References
-
ASTM International. Standard Test Method for Seal Strength of Flexible Barrier Materials. ASTM F88/F88M, 2023 edition. Publisher page
-
ASTM International. Standard Test Method for Burst Testing of Flexible Package Seals Using Internal Air Pressurization Within Restraining Plates. ASTM F2054/F2054M, 2013 edition, reapproved 2024. Publisher page
-
ASTM International. Standard Test Methods for Internal Pressurization Failure Resistance of Unrestrained Packages. ASTM F1140/F1140M, 2013 edition, reapproved 2025. Publisher page
-
ASTM International. Standard Test Method for Detecting Gross Leaks in Packaging by Internal Pressurization (Bubble Test). ASTM F2096, 2011 edition, reapproved 2019. Retailer page
-
ASTM International. Standard Test Method for Detecting Seal Leaks in Porous Medical Packaging by Dye Penetration. ASTM F1929, 2023 edition. Publisher page
-
ASTM International. Standard Practices for Making Laboratory Heat Seals for Determination of Heat Sealability of Flexible Barrier Materials as Measured by Seal Strength. ASTM F2029, 2016 edition, reapproved 2021. Retailer page
-
ISO. Packaging for terminally sterilized medical devices. Part 1: Requirements for materials, sterile barrier systems and packaging systems. ISO 11607 Part 1, 2019 edition, confirmed 2024, with Amendment 1 of 2023 on application of risk management. Standards body page
-
ISO. Packaging for terminally sterilized medical devices. Part 2: Validation requirements for forming, sealing and assembly processes. ISO 11607 Part 2, 2019 edition, confirmed 2024. Standards body page
-
M. Merabtene, P. Tanninen, J. Varis and V. Leminen. Heat Sealing Evaluation and Runnability Issues of Flexible Paper Materials in a Vertical Form Fill Seal Packaging Machine. BioResources, volume 17, issue 1, pages 223 to 242, 2022. Article page
-
S. Farris, C. A. Cozzolino, L. Introzzi and L. Piergiovanni. Effects of different sealing conditions on the seal strength of polypropylene films coated with a bio based thin layer. Packaging Technology and Science, volume 22, issue 6, pages 359 to 369, 2009. Article page
-
A. Hassan, S. Y. Cheng, M. I. Ghazali and A. F. Ismail. Heat Sealability of Laminated Films with LLDPE and LDPE as the Sealant Materials in Bar Sealing Application. Journal of Applied Polymer Science, volume 104, issue 6, pages 3736 to 3745, 2007. University repository page
-
S. Franks. Strength and integrity, part two: Basics of seal strength testing. Packaging Digest, 4 January 2016. Article page
-
S. Franks. Strength and integrity, part one: The basics of medical package testing. Packaging Digest, 4 January 2016. Article page
-
Thwing Albert Instrument Company. Hot tack guide (product brochure), used only for the definition of early seal strength. Brochure
Related Posts