HDT & Vicat Softening Point Tester

HDT&Vicat Softening Point Tester for Determining Heat Deflection and Vicat Softening Temperatures

HDT & Vicat Softening Point Tester1 / 2
TS-HVST100

HDT & Vicat Softening Point Tester

Three-station laboratory instrument designed to determine the Heat Deflection Temperature (HDT) and Vicat Softening Temperature (VST) of non-metallic materials.

Key Specifications

Temperature Range

Ambient ~ 300°C

Temperature Accuracy

±0.5°C

Deformation Range

0–10 mm

Test Stations

3

HDT&Vicat Softening Point TesterHeat Deflection TemperatureVicat Softening PointPlastic Testing

Global Shipping

50+ countries

2-Year Warranty

Parts & service

Expert Support

Dedicated team

Have a question about this instrument?

Talk to an expert

Product Information

The HDT&Vicat Softening Point Tester (Model: TS-HVST100) is a three-station instrument for testing non-metallic materials. It is designed and manufactured in accordance with the latest international and national standards and is primarily used to determine the Heat Deflection Temperature (HDT) and Vicat Softening Point Temperature (VST) of materials such as plastics, hard rubber, nylon, and electrical insulation materials.

Convenient to operate and precisely controlled, the tester is widely used in universities, research institutions, and product quality supervision and inspection units.

Key Features

  • Three-station testing design for non-metallic materials.
  • Designed for determining Heat Deflection Temperature (HDT) and Vicat Softening Point Temperature (VST).
  • Temperature control with an accuracy of ±0.5°C and resolution of 0.01°C.
  • Distributed control system using single-chip microcomputer and PC.

Technical Parameters

ParameterSpecification
Temperature Control RangeAmbient temperature ~ 300°C
Temperature Accuracy±0.5°C
Temperature Resolution0.01°C
Heating Rate50°C/h, 120°C/h
Temperature Measurement Points4 (1 main, 1 for each of the 3 stations)
Deformation Measurement Range0mm ~ 10mm
Deformation Resolution0.001mm
Deformation Accuracy±0.004mm
Medium UsedMethyl Silicone Oil (to be provided by customer)
Specimen Support Span64mm, 100mm
Cooling MethodWater circulation air-cooling system
Upper temperature limit protection function
Number of Test Stations3
Control MethodDistributed control system using single-chip microcomputer and PC
Instrument Dimensions820mm X 550mm X 1450mm
Required Space1m front/back, 0.6m left/right
Power Supply4500VA, 220VAC, 50Hz

Applications

  • Plastics Testing: Determination of Heat Deflection Temperature (HDT) and Vicat Softening Point Temperature (VST).
  • Hard Rubber Testing: Evaluation of thermal softening properties.
  • Nylon Testing: Measurement of HDT and VST.
  • Electrical Insulation Materials: Thermal performance testing of non-metallic insulation materials.
Related Products